TÜV approved particulate monitor providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge Filters
FEATURES & BENEFITS
Robust design unaffected by product build-up on the sensor rod
No additional services such as air purge required, providing lower cost of ownership
Simple maintenance no requirement for specialist service personnel
Networking of sensor channels and providing multiple inputs and outputs for external connections
Extensively used for measurement (mg/m³) and leak location in bag filter stack applications
Advanced sensor design includes drift checks (zero and span) and contamination checks
Passive/Active and fully insulated sensor options available for applications with stack condensation and damp particulate prevents potential short circuit to stack wall
MAIN APPLICATIONS
- Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
- After process dryers
- Variable velocities within range 8 – 20 m/s
- (typical bag filter velocity ranges), constant velocity required outside this range
- Non-condensing / dry flue gases
Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg Detergent / Carbon Black)
- Power Generation Plant (eg Coal/Biomass)
TECHNICAL SPECIFICATIONS |
Measured parameters |
Dust |
Technology |
ElectroDynamic™ Advanced Probe Electrification |
Measurement/Monitoring capability |
0-1000 mg/m³* |
Stack/Duct diameter suitability |
up to 8m |
Flue gas temperature |
up to 800°C |
Baghouse |
YES |
Cartridge Filter |
YES |
Ceramic Filter |
YES |
Coalescent Filter |
YES |
Cyclone |
YES |
Electrostatic Precipitator (ESP) |
/ |
Wet Electrostatic Precipitator (WESP) |
/ |
Wet Scrubber |
/ |
Sensor variants |
Stainless Steel Fully insulted PTFE coated Passive/Active |
QA checks |
YES |
*Application dependant
TECHNICAL DATA |
Measurement capability |
0 – 1000 mg/m3 |
Sensor Variants |
316 Stainless Steel / Fully insulated PTFE coated (option) / Passive/Active (option) |
Stack Temperature Ranges |
0 -250°C up to 800°C (option) |
Functionality and QA Checks |
Automatic zero and span / Short circuit check / Contamination check / Drift checks |
Data Output |
RS485 (Modbus) output to Controller |
Air Purge |
option |
Enclosure Protection Rating |
IP66 |
APPROVALS & CERTIFICATIONS
- TÜV approved BlmSchV 13, 17 & 27
- Ex Zone 2, 20